Analyze the water test procedure of cast iron pipe shares by Malleable Iron Pipe Fittings Supplier China.
1. Clean the area around the reserved cast iron pipe mouth, remove the pipe plug, and check whether there are sundries in the pipe. Find the center line of the outlet and draw it on the wall.
2. The next water pipe bearing mouth on sand, squat toilet position under the bedding lime, and then the squat toilet outlet into the drainage pipe bearing mouth inside the stable. At the same time with a horizontal ruler on the squat toilet along the vertical and horizontal two-way leveling, alignment. Align the squat toilet inlet with the center line on the wall.
3. Squatting toilet on both sides with brick good wipe flat, squatting toilet outlet and drainage pipe bearing mouth contact sand ash compaction, wipe light. Finally, the squatting toilet outlet is temporarily blocked and sealed.
4. When installing multiple squat toilets stably, check whether the drainage pipe elevation and the distance between the swing port and the wall are consistent. Find out standard ground level, measure up the height that good crouch implement needs, with small line level, find good metope distance, press afore - mentioned method to undertake steadily installation one by one next.